Automatic screw counting machine hardware store screw counting machine screw counting screw counter 220V/110V
Features:
1.The number 0-9999 can be set arbitrarily
2.With high precision counter
3.A wide range of applications, the size of the track is adjustable from 1.0 to 5.0
4.Simple and light, can work on the table
5.Convenient and fast, the output speed is about 90PCS/min
Specifications:
Product name:Automatic screw counting machine
Product model:FA-590A
Applicable range:Suitable for various types of screws (longest L=20mm)
Applicable screws:Screw diameter 1.0-5.0mm (adjustable)
Output speed:2 grains/sec
Input voltage:AC220V
Product size:125*180*150mm
Net weight:3.3kg
Screw capacity:[M1: about 1500 pcs][M2: about 1000 pcs][M3: about 600 pcs][M4: about 300 pcs][M5: 200 pcs]
Counting screw machine mode setting
Manual mode setting:
1.Select manual mode: In the shutdown state, press and hold the B button, then press the power button to turn on, display E000 (manual reset mode), then press the A button to switch to
E001 (automatic reset mode), press the A key to switch between manual mode and automatic mode and finally press the F key to confirm save and exit
2.Fixed number setting: In the power-on state, long press the A button (press and hold), it will start to count down, after the beep, release the A button to display d010 (factory default setting 10
A), press the A key to add processing, and press the B key to subtract processing. After setting properly, finally press F key to confirm save and exit.
Auto mode setting:
1.Select automatic mode: In the shutdown state, press and hold the B button, and then press the power button to turn on, and E001 (automatic reset mode) is displayed, if it is not E001, you can
Press the A key to switch to E001. It is best to press F key to confirm save and exit.
2.Delay setting: In the power-on state, long press the B button (press and hold), it will start to count down, after the buzzer, release the B button, and display FF03 (the factory default is 3 seconds delay
Hour), press the A key to add processing, and press the B key to subtract processing. After setting up properly, finally press the F key to confirm save and exit
3.Fixed number setting: In the power-on state, long press the A button (press and hold), it will start to count down, after the beep, release the A button to display d010 (factory default setting 10
A), press the A key to add processing, and press the B key to subtract processing. After setting properly, it is best to press F key to confirm save and exit.